[Image]
[Image]                 [Image]     [Image]     [Image]    [Image]
[Image]     [Image]                                                    [Image]     [Image]
[Image]                             [Image]       [Processors]
       [support.intel.com resources]
                                                              [Processors]
       [Image]  Pentium II                [Image]            [*]
                Processors Home
       [Image]
       [Image]  Software & Drivers
       [Image]                                    Pentium II Processors
       [Image]  Specification &                   "Runtime Error 200", "Divide Overflow", "Divide by 0"
                Errata                            errors when running software that was compiled on a
       [Image]                                    Borland TurboPascal* compiler.
       [Image]  Installation & Use
       [Image]                                    A "Runtime Error 200", "Divide Overflow", or a "Divide by
       [Image]  Warranty Information              0" error message that is displayed when you try to run a
       [Image]                                    program may be a result of a timing loop that affects any
       [Image]  Email Support                     program compiled on Borlands TurboPascal* compiler. All
                                                  versions (including version 7.0) of Borlands TurboPascal
       [other resources]                          compilers are affected by this issue. This compiler
                                                  problem is dependent on the speed the processor is
       [Image]  Intel Processor                  running, but it is not a processor issue.
                Frequency ID Utility
       [Image]                                    When executed at speeds greater than or equal to 233 MHz,
       [Image]  Manuals                           a speed-dependent timing loop in the compiled program
       [Image]                                    generates a large number. The code following the timing
       [Image]  Performance                       loop then attempts to divide this large number by a
                Indicators                        smaller constant number. This division results in a
       [Image]                                    quotient too large to be represented in the quotient
       [Image]  Spec Update                       register designated by the specific divide instruction.
                                                  The program will not run, and the system displays the
                                                  "Runtime Error 200" message, or a "Divide Overflow" error
       [Image]                                    message.
                                           [Image]
                                                  The root cause of this problem appears to be the software
                                                  libraries that come with the compiler. Any compilers that
                                                  are dependent on software-based timing loops are affected,
                                                  but this issue is specifically known to affect Borlands
                                                  TurboPascal compilers.

                                                  If you have a piece of software that was compiled on a
                                                  Borland Turbo Pascal compiler, you will likely encounter
                                                  this problem when run at speeds of 233 MHz and higher. One
                                                  possible solution is to contact your software vendor to
                                                  see if they have a newer version of that software that is
                                                  not dependent on timing loops.

                                                  Intel is also aware of two patches for this problem, one
                                                  for programs that have been compiled with a Borland
                                                  TurboPascal compiler, and one that will patch the software
                                                  libraries of the compiler itself.

                                                  Intel has worked with Inprise (formerly Borland), and
                                                  Inprise has communicated that there is more information
                                                  about this problem on the Inprise Developer Support web
                                                  site.


                                                  [Back to Top]

                                           [Image]
                                                  * Legal Information and Privacy Policy  2001 Intel
                                                  Corporation
[Image]                 [Image]